| Application/type |
Room controller |
| Purpose |
Room Climate Control, Measure values |
| Measured values |
temperature, relative humidity |
| Interface |
Active, 0..10 V, RS485 Modbus, Switch contact |
| On stock |
No |
| Functions |
temperature control, fan control, heating + cooling relay, heating + cooling 0..10 V, heating relay, cooling 0..10 V, integrated controller, presence |
| Operating functions |
setpoint adjustment temperature, setpoint adjustment OK/cancel, fan stage adjustment, presence detection |
| Operating elements |
4 buttons |
| Configuration |
BUS, buttons, DIP switches |
| Output voltage |
0..10 V, 2x 0..10 V, min. load 1 kΩ, min. load 10 kΩ, cooling, heating + cooling or to control 6-way control valve, temperature actual value and setpoint |
| Output switch contact |
2x contact NO, 1x heating, 1x cooling, 1x output triac, heating, 2x output triac, 1x heating, 1x cooling, load max. 3 A, load max. 1 A, for 24 V =/~, for 24 V ~, floating |
| Input |
2x input digital for floating switch contact, 4x input digital for floating switch contact |
| Network technology |
RS485 Modbus |
| Data transmission |
RTU, half-duplex, baud rate 9.600, 19.200, 38.400 or 57.600, parity: none (2 stop bits), even or odd (1 stop bit) |
| Operating range temperature (°C) |
0..+50 |
| Operating ranges temperature (°C) |
0..+50 |
| Output signal temperature |
0..+50 °C |
| Operating range humidity |
max. 85% rH non-condensing |
| Accuracy temperature |
±0,5 K (typ. at 21 °C) |
| Measuring range humidity |
0..100% rH non-condensing |
| Accuracy humidity |
±2% between 10..90% rH (typ. at 21 °C) |
| Power supply |
15..24 V = (±10%) SELV, 24 V ~ (±10%) SELV |
| Power consumption |
typ. 0,9 W (24 V =), 1 VA (24 V ~) |
| Enclosure |
PC |
| Colour |
white, pure white brilliant, pure white matt, aluminium, Jung aluminium |
| Protection (IP) |
IP30, according to EN 60529 |
| Connection |
terminal block, max. 1,5 mm², pluggable |
| Switch ranges |
Berker, Busch-Jaeger, Feller, Gira, Jung, Merten, Peha, (please specify the desired frame when ordering) |
| Switch range Berker |
S.1, B.3 aluminium, B.7, B.7 glass, Q.1, Q.3, K.5 aluminium/stainless steel |
| Switch range Busch-Jaeger |
alpha nea®, Busch-axcent® with intermediate frame, Busch-balance® SI, Busch-Duro 2000® SI, future® linear with intermediate frame, Reflex SI, solo® with intermediate frame |
| Switch range Feller |
EDIZIOdue, STANDARDdue |
| Switch range Gira |
E2, E3, Esprit, Event, Flächenschalter with intermediate frame, Standard 55 |
| Switch range Jung |
A 500, A 550, A creation, A plus, AS 500, CD 500 with intermediate frame, LS 990 with intermediate frame |
| Switch range Merten |
1-M, Antik with intermediate frame, Artec with intermediate frame, Artec stainless steel with intermediate frame, Atelier-M, M-Arc, M-Plan, M-Pure, M-Smart |
| Switch range Peha |
Aura, Aura glass |
| Mounting |
flush-mounted in standard EU box (Ø=60 mm, depth min. 45 mm), DO2T, DO2R, OVR, OVT with IO extension need 2 flush-mounting boxes (Ø=60 mm) and double frame (alternatively, the IO unit can be mounted in a deep flush-mounted box or be detached up to 10 m) |
| Packaging length (mm) |
90 |
| Packaging width (mm) |
90 |
| Packaging height (mm) |
80 |
| Packaging |
case packaging |
| Device length (mm) |
77 |
| Device width (mm) |
77 |
| Device height (mm) |
38 |
| Gefahrgut |
No |