Room sensor in the NOVOS 3 enclosure for measurement of temperature (also available with passive temperature output), humidity (relative and absolute humidity, enthalpy, dew point), CO2 and mixed gas (VOC) depending on the variant. The maintenance-free sensor contributes to a pleasant room climate and well-being. Typical applications include schools, office buildings, hotels or cinemas. Different parameters can be individually configured via Thermokon NOVOSapp or uConfig. Optionally, operating elements for controlling HVAC systems can be added (see product NOVOS 3 x in the chapter 'Room Operating Units').
Application/type | Room sensor |
---|---|
Purpose | Measure values |
Measured values | temperature, relative humidity, absolute humidity, enthalpy, dew point, CO2, VOC, CO2/VOC mix |
Interface | Active, 0..5 V, 0..10 V, 4..20 mA |
Configuration | NOVOSapp, uConfig, each output can be set to get a variable mix of CO2 and VOC by configuration via app or uConfig, (depending on type) |
Output voltage | 0..10 V or 0..5 V, 2x 0..10 V or 0..5 V, 3x 0..10 V or 0..5 V, 4x 0..10 V or 0..5 V, live-zero configuration via app or uConfig, min. load 10 kΩ |
Output current | 4..20 mA, 2x 4..20 mA, max. load 500 Ω |
Operating range temperature (°C) | 0..+50 |
Operating ranges temperature (°C) | 0..+50 |
Output signal temperature | 0..+50 °C (default setting), selectable from 4 temperature ranges -40..+60 | 0..+50 | -20..+80 | -15..+35 °C -50..+50 | 0..+50 | -20..+80 | -15..+35 °C, optionally configurable |
Operating range humidity | max. 85% rH non-condensing |
Accuracy temperature | ±0,5 K (typ. at 21 °C) |
Measuring range humidity | 0..100% rH non-condensing, 0..85 KJ/kg enthalpy, 0..50 | 0..80 g/m³ absolute humidity, 0..+50 | -20..+80 °C dew point, optionally configurable |
Accuracy humidity | ±2% between 10..90% rH (typ. at 21 °C) |
Measuring range CO2 | 0..2000 ppm, 0..5000 ppm, optionally configurable |
Accuracy CO2 | ±50 ppm +3% of measured value (typ. at 21 °C, 50% rH, 1015 hPa), self-calibration Dual Channel |
Measuring VOC (mixed gas) | heated metal oxide semiconductor |
Power supply | 15..35 V = SELV, 19..29 V ~ SELV |
Power consumption | typ. 0,4 W (24 V =), 0,8 VA (24 V ~) |
Display | ePaper Display 44x24 mm, with traffic light function, threshold values configurable, optionally configurable via app or uConfig |
Enclosure | PC V0 |
Colour | pure white, aluminium, black |
Protection (IP) | IP20, according to EN 60529 |
Connection | tool-free mountable spring clamp, max. 1,5 mm², cable entry via rear opening, predetermined breaking point (bottom) or drilling mark (top) |
Mounting | flush-mounted on standard EU box (Ø=60 mm), flush-mounted in standard EU box (Ø=60 mm, depth min. 45 mm), surface-mounted flat on base using adhesive foil or screws, base part can be mounted and wired separately |
Packaging length (mm) | 115 |
Packaging width (mm) | 105 |
Packaging height (mm) | 30 |
Packaging | case packaging |
Device length (mm) | 110 |
Device width (mm) | 100 |
Device height (mm) | 23 |
Notes | + surcharge for design cover (mandatory), please select colour, mixed gas sensors detect gases and vapours which can be oxidised (burnt): Body odours, tobacco smoke, exhalations emitted by materials (furniture, carpets, paint, glue ...) |
Option enclosure | ePaper Display 44x24 mm |
Vorschau | Name |
---|---|
uConfig_Setup_WIN.zip |
Vorschau | Name |
---|---|
NOVOS_3_Header.jpg | |
NOVOS_3_weiß.jpg | |
NOVOS_3_TD_weiß.jpg | |
NOVOS_3_schwarz.jpg | |
NOVOS_3_TD_schwarz.jpg | |
NOVOS_3_alu.jpg | |
NOVOS_3_TD_alu.jpg |
No tender texts available