The NOVOS 7 stands out for its well-known and intuitive user interface using a rotary push button and a 3.5" TFT display. Four favourite buttons allow quick access to frequently used functions such as temperature set point or light control. Blinds and lights can thus be configured accordingly. The NOVOS 7 can be equipped with up to 4 integrated sensors (temperature, relative humidity, CO2 and VOC) and contributes to a comfortable room ambience and energy savings.
Application/type | Room operating unit |
---|---|
Purpose | Room Climate Control, Lighting control, Scene control, Shading control, Measure values |
Measured values | temperature, relative humidity, absolute humidity, enthalpy, dew point, CO2, VOC, CO2/VOC mix |
Interface | Casambi (BLE), RS485 Modbus, RS485 BACnet, KNX (TP) |
Functions | temperature control, fan control, change-over, window/door monitoring, presence, lighting, blinds/shutter |
Operating functions | setpoint adjustment temperature, fan stage adjustment, presence detection, light ON/OFF/DIM, blind UP/DOWN/SET, setup scenarios, ECO function, showing measured value and history |
Operating elements | rotary push button, 4 favourite buttons |
Configuration | NOVOSapp, App, uConfig, BUS, ETS (KNX), (depending on type) |
Input | 1x input for NTC10k or floating contact, 1x input for floating contact, 2x input for floating contact |
Network technology | RS485 Modbus, RS485 BACnet (MS/TP), KNX (TP1) |
Radio technology | 2,4 GHz, Casambi (BLE) |
Data transmission | RTU, half-duplex, baud rate 9.600, 19.200, 38.400 or 57.600, parity: none (2 stop bits), even or odd (1 stop bit) |
Operating range temperature (°C) | 0..+50 |
Output signal temperature | 0..+50 °C (default setting), selectable from 4 temperature ranges -40..+60 | 0..+50 | -20..+80 | -15..+35 °C -50..+50 | 0..+50 | -20..+80 | -15..+35 °C, optionally configurable |
Operating range humidity | max. 85% rH non-condensing |
Accuracy temperature | ±0,5 K (typ. at 21 °C), within default measuring range |
Measuring range humidity | 0..100% rH non-condensing, 0..85 KJ/kg enthalpy, 0..50 | 0..80 g/m³ absolute humidity, 0..+50 | -20..+80 °C dew point, optionally configurable |
Accuracy humidity | ±2% between 10..90% rH (typ. at 21 °C) |
Measuring range CO2 | 0..2000 ppm, 0..5000 ppm, optionally configurable |
Accuracy CO2 | ±50 ppm +3% of measured value (typ. at 21 °C, 50% rH, 1015 hPa), self-calibration Dual Channel |
Measuring VOC (mixed gas) | heated metal oxide semiconductor |
Power supply | 24 V = (±10%) SELV, 24 V ~ (±10%) SELV |
Power consumption | typ. 2 W (24 V =), 4 VA (24 V ~) |
Display | TFT 3,5", 320x480 px |
Enclosure | PC V0 |
Colour | pure white, aluminium, black |
Protection (IP) | IP30, according to EN 60529 |
Connection | tool-free mountable spring clamp, max. 1,5 mm², removable plug-in terminal, max. Ø=0,8 mm, cable entry via rear opening, predetermined breaking point (bottom) or drilling mark (top) |
Mounting | flush-mounted on standard EU box (Ø=60 mm), flush-mounted in standard EU box (Ø=60 mm, depth min. 45 mm), surface-mounted flat on base using adhesive foil or screws, base part can be mounted and wired separately |
Packaging length (mm) | 170 |
Packaging width (mm) | 110 |
Packaging height (mm) | 45 |
Device length (mm) | 163 |
Device width (mm) | 106 |
Device height (mm) | 28 |
Notes | mixed gas sensors detect gases and vapours which can be oxidised (burnt): Body odours, tobacco smoke, exhalations emitted by materials (furniture, carpets, paint, glue ...) |
No tender texts available