NOVOS 5 VOC

Room sensor in the NOVOS design for measuring mixed gas (VOC), temperature and humidity (relative, absolute, enthalpy, dew point) and displaying measured values through an integrated LCD with traffic light indication. The maintenance-free sensor forms the basis for a pleasant room climate and well-being. Especially designed for use in schools, office buildings, hotels, cinemas and similar applications. Threshold values and display settings can be configured individually via the Thermokon NOVOSapp. For models with set point and fan stage adjustment, please refer to the 'NOVOS 5 x' in the chapter 'Room Operating Units'.

Measured valuesVOC, temperature + humidity (depending on the device)
Output voltageV: 1x 0..10 V, VV: 2x 0..10 V, 3xV: 3x 0..10 V, 0..10 V or 0..5 V (live-zero can be configured via app or uConfig), min. load 10 kΩ
Output currentA: 1x 4..20 mA, AA: 2x 4..20 mA, 3xA: 3x 4..20 mA, max. load 500 Ω
Network technologyRS485 BACnet (MS/TP), RS485 Modbus
Power supply15..35 V = or 19..29 V ~ SELV
Measuring range temp.0..+50 °C
Measuring range humidity0..100% rH non-condensing, enthalpy: 0..85 KJ/kg, absolute humidity: 0..50 | 0..80 g/m³, dew point: 0..+50 | -20..+80 °C, optionally configurable via app, uConfig or BUS
Accuracy temperature±0,5 K (typ. at 21 °C)
Accuracy humidity±2% between 10..90% rH (typ. at 21 °C)
Calibrationself-calibration
SensorVOC sensor (heated metal oxide semiconductor)
InputsRS485 Modbus:, 1x input for floating contact
DisplayLCD 29x35 mm with RGB backlight, indicating air quality by switching display color (traffic light function ‘TLF’), Display and colours optionally configurable via app, uConfig or BUS
Colourpure white, black or aluminium
EnclosurePC V0, design cover pure white, black or aluminium
Protection (IP)IP30 according to EN 60529
Cable entryrear entry, breaking points bottom, drill mark top
Electrical connectiontool-free mountable spring clamp, max. 1,5 mm²
Ambient condition0..+50 °C, max. 85% rH non-condensing
Mountingflush-mounted on standard EU box (Ø=60 mm), or to be mounted flat onto the surface using screws, base part can be mounted and wired separately
Notesfor configuration an optional programming dongle (Bluetooth) is available (refer to accessories), mixed gas sensors detect gases and vapours which can be oxidised (burnt): Body odours, tobacco smoke, exhalations emitted by materials (furniture, carpets, paint, glue ...)
Contact

Contact us:


Thermokon Sensortechnik GmbH
Platanenweg 1
35756 Mittenaar
Tel.: +49 2778 6960-0


Write email


View contact