Room sensor in the new Thermokon enclosure NOVOS 5 for measuring CO2 content and additionally temperature and humidity (relative, absolute, enthalpy, dew point). The maintenance-free sensor creates the conditions for a pleasant indoor climate and well-being. Typical applications are schools, office buildings, hotels, cinemas or similar. The device has an LC display with color change function for displaying the measured values. The threshold values and display settings can be individually configured via the Thermokon NOVOSapp. For set point and fan stage adjustment, manual override for room and office applications please refer to NOVOS 5 x in 'Room Operating Units'.

Measuring valuesCO2, temperature + humidity (depending on the device)
Output voltageV: 1x 0..10 V, VV: 2x 0..10 V, 3xV: 3x 0..10 V, 0..10 V or 0..5 V (live-zero can be configured via Thermokon NOVOSapp), min. load 10 kΩ
Output ampereA: 1x 4..20 mA, AA: 2x 4..20 mA, 3xA: 3x 4..20 mA, max. load 500 Ω
Network technologyRS485 Modbus, RS485 BACnet (MS/TP)
Power supply15..35 V = or 19..29 V ~ SELV
Measuring range temp.0..+50 °C
Measuring range humidity0..100% rH non-condensing, enthalpy: 0..85 KJ/kg, absolute humidity: 0..50 | 0..80 g/m³, dew point: 0..+50 | -20..+80 °C, optionally configurable via Thermokon NOVOSapp or BUS
Measuring range CO20..2000 ppm | 0..5000 ppm (optionally configurable via Thermokon NOVOSapp or BUS)
Accuracy temperature±0,5 K (typ. at 21 °C)
Accuracy humidity±2% between 10..90% rH (typ. at 21 °C)
Accuracy CO2±50 ppm +3% of measured value (typ. at 21 °C, 50% rH, 1015 hPa)
Calibrationself-calibration, Dual Channel
SensorNDIR (non-dispersive, infrared)
InputsRS485 Modbus:, 1x input for floating contact
DisplayLCD 29x35 mm with RGB backlight, indicating air quality by switching display color (traffic light function ‘TLF’)
Colour
EnclosurePC V0, design cover pure white, other colours on request
ProtectionIP30 according to EN 60529
Cable entryrear entry, breaking points bottom, drill mark top
Connection electricaltool-free mountable spring clamp, max. 1,5 mm²
Ambient condition0..+50 °C, max. 85% rH non-condensing
Mountingsurface mounted on flush-mounting box (Ø=60 mm), or to be mounted flat onto the surface using screws, base part can be mounted and wired separately
Notesfor configuration an optional programming dongle (Bluetooth) is available (refer to accessories)