LA+

Air quality sensor for measuring CO2, mixed gas (VOC), temperature and humidity outdoors and in areas requiring high IP protection class (e.g. subway stations, tunnels, exhibition halls, cooling and greenhouses as well as in production halls and warehouses). If required, default values can be adjusted via Thermokon USEapp. For devices with CO2 and VOC, each output can be configured to be a mixed output (selectable signal ratio between CO2 and VOC). Devices with a relay option can be used as 2-point controllers or 2-step controllers.

Measuring values CO2, VOC, temperature + humidity (depending on the device), types CO2+VOC: each output can be set to get a variable mix of CO2 and VOC by configuration via Thermokon USEapp
Output voltage 1..3x 0..10 V or 0..5 V (adjustable via jumper; live-zero configuration via Thermokon USEapp), min. load 10 kΩ
Output ampere 1x/2x 4..20 mA, max. load 500 Ω
Output switch contact Relay: 2x floating contact NO for 24 V ~ or 24 V = / 3 A, (optional)
Network technology RS485 BACnet (MS/TP), RS485 Modbus
Power supply 15..35 V = or 19..29 V ~ SELV, A: 15..35 V = SELV
Power consumption max. 2,5 W (24 V =) | 4,3 VA (24 V ~)
Measuring range temp. -40..+60 °C | 0..+50 °C | -20..+80 °C | -15..+35 °C, default setting: 0..+50 °C, optionally configurable via Thermokon USEapp
Measuring range humidity 0..100% rH non-condensing, enthalpy: 0..85 KJ/kg, absolute humidity: 0..50 | 0..80 g/m³, dew point: 0..+50 | -20..+80 °C, optionally configurable via Thermokon USEapp
Accuracy temperature ±0,5 K (typ. at 21 °C within default measuring range)
Accuracy humidity ±2% between 10..90% rH (typ. at 21 °C)
Calibration self-calibration, CO2: Dual Channel
Sensor VOC sensor (heated metal oxide semiconductor), CO2: NDIR (non-dispersive, infrared)
Enclosure enclosure USE-M, PC, pure white, LCD: cover PC, transparent, with removable cable entry
Protection IP65 according to EN 60529
Cable entry Flextherm M16 for wire Ø=3..7 mm, Relay/BUS: M25 with fourfold cable entry for wire with max. Ø=7 mm, 3xV: M20 for wire max. Ø=8 mm incl. seal insert for double cable entry for wire max Ø=6 mm, removable
Connection electrical removable plug-in terminal, max. 2,5 mm², BUS terminal: removable plug-in terminal, max. 1,5 mm²
Ambient condition 0..+50 °C, max. 85% rH short term condensation
Delivery contents incl. mounting base enclosure USE-M pure white, incl. universal mounting set (cover screw, self-drilling screws, dowels, spax screws and screw cover)